14. USING A LINEAR SERVO MOTOR

14.4.2 Power supply capacity and generated loss

Table 14.1 indicates servo amplifiers' power supply capacities and losses generated under rated load. For
thermal design of an enclosed type cabinet, use the values in the table in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at rated
torque and servo-off according to the duty used during operation. When the linear servo motor is run at less
than the rated speed, the power supply capacity will be smaller than the value in the table, but the servo
amplifier's generated heat will not change.
Mounting a heat sink outside of the cabinet enables to reduce heat in the cabinet and design a compact
enclosed type cabinet.
Table 14.1 Power supply capacity and generated loss per linear servo motor at rated output
Linear servo motor
(primary side)
LM-H3P2A-07P-BSS0
LM-H3P3A-12P-CSS0
LM-H3P3B-24P-CSS0
LM-H3P3C-36P-CSS0
LM-H3P3D-48P-CSS0
LM-H3P7A-24P-ASS0
LM-H3P7B-48P-ASS0
LM-H3P7C-72P-ASS0
LM-H3P7D-96P-ASS0
LM-U2PAB-05M-0SS0
LM-U2PAD-10M-0SS0
LM-U2PAF-15M-0SS0
LM-U2PBB-07M-1SS0
LM-U2PBD-15M-1SS0
LM-U2PBF-22M-1SS0
LM-U2P2B-40M-2SS0
LM-U2P2C-60M-2SS0
LM-U2P2D-80M-2SS0
LM-FP2B-06M-1SS0
LM-FP2D-12M-1SS0
LM-FP2F-18M-1SS0
LM-FP4B-12M-1SS0
LM-FP4D-24M-1SS0
LM-FP4F-36M-1SS0
LM-FP4H-48M-1SS0
LM-FP5H-60M-1SS0
LM-K2P1A-01M-2SS1
LM-K2P1C-03M-2SS1
LM-K2P2A-02M-1SS1
LM-K2P2C-07M-1SS1
LM-K2P2E-12M-1SS1
LM-K2P3C-14M-1SS1
LM-K2P3E-24M-1SS1
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value is applicable when the
power factor improving AC reactor or power factor improving DC reactor are not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 11.2.
Power supply
Servo amplifier
capacity [kVA]
(Note 1)
0.9
MR-J4-40TM
MR-J4-40TM1
0.9
1.3
MR-J4-70TM
1.9
MR-J4-200TM
3.5
MR-J4-70TM
1.3
3.5
MR-J4-200TM
3.8
MR-J4-350TM
5.5
MR-J4-20TM
0.5
MR-J4-20TM1
0.9
MR-J4-40TM
MR-J4-40TM1
0.9
MR-J4-20TM
0.5
MR-J4-20TM1
MR-J4-60TM
1.0
MR-J4-70TM
1.3
MR-J4-200TM
3.5
MR-J4-350TM
5.5
MR-J4-500TM
7.5
MR-J4-200TM
3.5
MR-J4-500TM
7.5
MR-J4-700TM
10
MR-J4-500TM
7.5
MR-J4-700TM
10
MR-J4-11KTM
14
MR-J4-15KTM
18
MR-J4-22KTM4
22
MR-J4-40TM
0.9
MR-J4-40TM1
MR-J4-200TM
3.5
MR-J4-70TM
1.3
MR-J4-350TM
5.5
MR-J4-500TM
7.5
MR-J4-350TM
5.5
MR-J4-500TM
7.5
Servo amplifier-generated heat [W]
(Note 2)
At rated output
35
35
50
75
90
50
90
100
130
25
35
35
25
40
50
90
130
195
90
195
300
195
300
460
580
640
35
90
50
130
195
130
195
14 - 28
Area required for
heat dissipation
2
[m
With servo-off
15
0.7
15
0.7
15
1.0
15
1.5
20
1.8
15
1.0
20
1.8
20
1.1
20
2.7
15
0.5
15
0.7
15
0.7
15
0.5
15
0.8
15
1.0
20
1.8
20
2.7
25
3.9
20
1.8
25
3.9
25
6.0
25
3.9
25
6.0
45
9.2
45
11.6
45
12.8
15
0.7
20
1.8
15
1.0
20
2.7
25
3.9
20
2.7
25
3.9
]