15. USING A DIRECT DRIVE MOTOR
(c) State transition of the servo amplifier display (3-digit, 7-segment LED) at the magnetic pole detection
When the magnetic pole detection with MR Configurator2 is normally executed, the servo amplifier
display (3-digit, 7-segment LED) shows the state as below.
(2) Preparation for the magnetic pole detection
For the magnetic pole detection, use the test operation mode (positioning operation) of MR
Configurator2. Turn off the servo amplifier power, and set the test operation select switch (SW1-1) as
shown below. Turning on the power enables the test operation mode.
Servo-off status
POINT
When you select the test operation mode with the test operation select switch
(SW1-1), the network communication for the servo amplifier and later will be
blocked.
Magnetic pole
During the
detection
magnetic
completed
pole detection
(Servo-on status)
The decimal point flickers.
ON
1
2
15 - 9
ON
1
2
Set SW1-1 to "ON (up)".