11. OPTIONS AND PERIPHERAL EQUIPMENT
(2) 400 V class
FR-CV-H power regeneration common converter can be used for the servo amplifier of 11 kW to 22 kW.
The following shows the restrictions on using the FR-CV-H.
(a) Up to two servo amplifiers can be connected to one FR-CV-H.
(b) FR-CV-H capacity [W] ≥ Total of rated capacities [W] × 2 of servo amplifiers connected to FR-CV-H.
(c) The total of used servo motor rated currents should be equal to or less than the applicable current
[A] of the FR-CV-H.
(d) Among the servo amplifiers connected to the FR-CV-H, the servo amplifier of the maximum capacity
should be equal to or less than the maximum connectable capacity [W].
The following table lists the restrictions.
When using the FR-CV-H, always install the dedicated stand-alone reactor (FR-CVL-H).
Item
Maximum number of connected servo
amplifiers
Total of connectable servo amplifier
capacities [kW]
Total of connectable servo motor rated
currents [A]
Maximum servo amplifier capacity [kW]
Power regeneration common
converter
FR-CV-H22K(-AT)
FR-CV-H30K(-AT)
FR-CV-H37K
FR-CV-H55K
11 - 39
22K
30K
11
43
11
Dedicated stand-alone
reactor
FR-CVL-H22K
FR-CVL-H30K
FR-CVL-H37K
FR-CVL-H55K
FR-CV-H_
37K
55K
1
2
15
18.5
27.5
57
71
110
15
15
22

Advertisement