5. PARAMETERS
No./
Setting
symbol/name
digit
PE34
Set a numerator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
**FBN2
Set the electronic gear so that the number of servo motor encoder pulses for one
Fully closed
servo motor revolution is converted to the resolution of the load-side encoder.
loop control -
Feedback
For details, refer to section 16.3.1 (5).
pulse
electronic
Setting range: 1 to 65535
gear 2 -
Numerator
PE35
Set a denominator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
**FBD2
Set the electronic gear so that the number of servo motor encoder pulses for one
Fully closed
servo motor revolution is converted to the resolution of the load-side encoder.
loop control -
Feedback
For details, refer to section 16.3.1 (5).
pulse
electronic
Setting range: 1 to 65535
gear 2 -
Denominator
PE41
_ _ _ x Robust filter selection
EOP3
0: Disabled
Function
1: Enabled
selection E-3
When "Enabled" is set, the machine resonance suppression filter 5 that is set in [Pr.
PB51] is not available.
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _
Function
5 - 60
Initial
Network
value
ECT EIP
[unit]
1
1
0h
0h