5. PARAMETERS
No./
Setting
symbol/name
digit
PT72
Set an electronic gear numerator for converting a synchronous encoder command
ECMXL
into a command unit. Upper and lower are a set.
Synchronous
Set the electronic gear in hexadecimal.
encoder
electronic
Setting value of this parameter:
gear -
Numerator
(lower four
digits)
Set a value within the following range. When a value outside the range is set,
synchronous control error will occur and synchronous control will not start even
though Synchronous control command (Control DI7 bit 12) is input.
Setting "0" will apply "1".
16000
To enable the parameter value, cycle the power or turn on Analysis command
(Control DI 7 bit 14).
This parameter corresponds to "External encoder gear numerator (Class ID: 64h, Ins
ID: 2DF0h, Attr ID: 1)". When this parameter is mapped for the I/O communication,
the value written with MR Configurator2 is overwritten with the controller. Thus, do
not write a value with MR Configurator2.
Setting range: 0000h 0000h to FFFFh FFFFh
PT73
Set an electronic gear numerator for converting a synchronous encoder command
ECMXH
into a command unit. Upper and lower are a set.
Synchronous
Refer to [Pr. PT72] for details.
encoder
electronic
gear -
Numerator
(upper four
digits)
1
Synchronous encoder electronic gear - Numerator
<
Synchronous encoder electronic gear - Denominator
Function
Upper four
Lower four
digits
digits
[Pr. PT72]
[Pr. PT73]
5 - 81
Initial
value
[unit]
0000h
< 6000
0000h
Network
ECT EIP

Advertisement