11. OPTIONS AND PERIPHERAL EQUIPMENT

11.4 FR-RC-(H) power regeneration converter

When using the FR-RC-(H) power regeneration converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr. PC20] to
"_ _ _ 1".
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to the
servo amplifiers of the 5 kW to 22 kW.
Power regeneration
converter
FR-RC-15K
FR-RC-30K
FR-RC-55K
FR-RC-H15K
FR-RC-H30K
FR-RC-H55K
POINT
When using the FR-RC-(H) power regeneration converter, set [Pr. PA04] to
"0 0 _ _" to enable EM1 (Forced stop 1).
When using the FR-RC-(H) power regeneration converter, refer to "Power
Regeneration Converter FR-RC Instruction Manual (IB(NA)66330)".
Nominal
regenerative
Servo amplifier
power [kW]
MR-J4-500TM
15
MR-J4-700TM
MR-J4-11KTM
30
MR-J4-15KTM
55
MR-J4-22KTM
MR-J4-500TM4
15
MR-J4-700TM4
MR-J4-11KTM4
30
MR-J4-15KTM4
55
MR-J4-22KTM4
500
300
200
100
50
30
20
11 - 33
0
50
75
100
Nominal regenerative power [%]
150