APPENDIX
App. 10.2 Magnetic contactor
Use a magnetic contactor with an operation delay time (interval between current being applied to the coil
until closure of contacts) of 80 ms or less.
Magnetic
Servo amplifier
contactor
MR-J4-10TM
MR-J4-20TM
MR-J4-40TM
SD-N11
SD-T12
MR-J4-60TM
MR-J4-70TM
MR-J4-100TM
MR-J4-200TM
SD-N21
SD-T21
MR-J4-350TM
MR-J4-500TM
SD-N35
MR-J4-700TM
SD-N50
MR-J4-11KTM
MR-J4-15KTM
SD-N65
MR-J4-22KTM
SD-N95
App. - 52
Magnetic
Servo amplifier
contactor
MR-J4-60TM4
SD-N11
MR-J4-100TM4
SD-T12
MR-J4-200TM4
MR-J4-350TM4
SD-N21
MR-J4-500TM4
SD-T21
MR-J4-700TM4
MR-J4-11KTM4
SD-N25
MR-J4-15KTM4
SD-N35
MR-J4-22KTM4
SD-N50
MR-J4-10TM1
MR-J4-20TM1
SD-N11
MR-J4-40TM1