Mitsubishi Electric MR-J4-TM Instruction Manual page 156

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

5. PARAMETERS
No./
Setting
symbol/name
digit
PA04
_ _ _ x For manufacturer setting
*AOP1
_ _ x _
Function
_ x _ _ Servo forced stop selection
selection A-1
0: Enabled (The forced stop input EM2 or EM1 is used.)
1: Disabled (The forced stop input EM2 and EM1 are not used.)
Refer to table 5.2 for details.
x _ _ _ Forced stop deceleration function selection
0: Forced stop deceleration function disabled (EM1)
2: Forced stop deceleration function enabled (EM2)
Refer to table 5.2 for details.
Setting
value
0 0 _ _
2 0 _ _
0 1 _ _ Not using
2 1 _ _ Not using
Table 5.2 Deceleration method
EM2/EM1
EM2 or EM1 is off
EM1
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
EM2
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
EM2 or EM1
EM2 or EM1
Function
Deceleration method
Alarm occurred
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
5 - 17
Initial
Network
value
ECT EIP
[unit]
0h
0h
0h
2h

Advertisement

Table of Contents
loading

Table of Contents