◆ A2: User Parameters

A2-01 to A2-32: User Parameters 1 to 32
The user can select 32 parameters and assign them to A2-01 through A2-32. This saves time later scrolling through the
parameter menu. The list of User Parameters can also track the most recently edited settings and save those parameters to
this list.
No.
A2-01 to A2-32
<1> This drive allows parameters that are adjusted frequently to be saved as user parameters A2-01 to A2-22 so that they can be set and
referred to easily.
Table 2.5 Parameter Registered as User Parameters (A2-01 to A2-22)
No.
A1-02
b1-01
b1-02
b1-03
C1-01
C1-02
d1-01
d1-02
d1-03
d1-04
d1-17
E1-04
E1-05
Saving User Parameters
To save specific parameters to A2-01 to A2-32, first set the access level to allow access to all parameters (A1-01 = 2).
Next assign the parameter number to the User Parameters list by entering it into one of the A2-
is then set to 1, the access level can be restricted so that users can only set and refer to the specific parameters saved as
User Parameters.
A2-33: User Parameter Automatic Selection
A2-33 determines whether or not parameters that have been edited are saved to the User Parameters (A2-17 to A2-32) for
quick, easy access.
No.
A2-33
User Parameter Automatic Selection
Setting 0: Do not save list of recently viewed parameters.
To manually select the parameters listed in the User Parameter group, set A2-33 to 0.
Setting 1: Save history of recently viewed parameters.
By setting A2-33 to 1, all parameters that were recently edited will be automatically saved to A2-17 through A2-32. A
total of 16 parameters are saved with the most recently edited parameter set to A2-17, the second most recently to A2-18,
and so on. User Parameters can be accessed using the Setup Mode of the digital operator.
YASKAWA ELECTRIC EZZ010930 FSDrive-MV1000 Parameter Guide
Name
User Parameters 1 to 32
Name
Control Method Selection
Frequency Reference Selection 1
Run Command Selection 1
Stopping Method Selection
Acceleration Time 1
Deceleration Time 1
Frequency Reference 1
Frequency Reference 2
Frequency Reference 3
Frequency Reference 4
Jog Frequency Reference
Maximum Output Frequency
Maximum Voltage
Name
Setting Range
b1-01 to o4-
No.
E1-06
E1-09
E1-13
E2-01
E2-04
E2-11
H4-02
H4-12
H4-22
H4-32
L1-01
L3-04
Setting Range
0 or 1
2.1 A: Initialization
Default
0
Name
Base Frequency
Minimum Output Frequency
Base Voltage
Motor Rated Current
Number of Motor Poles
Motor Rated Power
Analog Output 1 Gain
Analog Output 2 Gain
Analog Output 3 Gain
Analog Output 4 Gain
Motor Overload Protection
Selection
Stall Prevention during
Deceleration
parameters. If A1-01
Default
0