No.
Name
(Hex.)
A1-05
Password Setting
(0105)
A1-06
Application Preset
(0127)
A1-07
DriveWorksEZ
Function Selection Sets the drive for operation with a program created in
(0128)
A1-11
Firmware update
lock
(111D)

A2: User Parameters

No.
Name
(Hex.)
A2-01 to
User Parameters 1
A2-32
to 32
(0106 -
0125)
A2-33
User Parameter
Auto Selection
(0126)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
The drive locks the following parameters once the password has
been set. The following parameters can be changed if the user enters
the correct password in A1-04 [Password] that matches the
password set in A1-05.
• A1-01 [Access Level Selection]
• A1-02 [Control Method Selection]
• A1-03 [Initialize Parameters]
• A1-06 [Application Preset]
• A1-07 [DriveWorksEZ Function Selection]
• A2-01 to A2-32 [User Parameters 1 to 32]
V/f
CL-V/f
OLV
CLV
AOLV
This parameter conveniently sets up the drive for certain
applications.
0 : Disabled
1 : Water supply pump
2 : Conveyor
3 : Exhaust fan
4 : HVAC
5 : Air compressor
6 : Hoist
7 : Traveling
V/f
CL-V/f
OLV
CLV
AOLV
DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Digital input
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables the firmware update function via cloud service.
0 : Disable
1 : Enable
Description
V/f
CL-V/f
OLV
CLV
AOLV
The user can select up to 32 parameters for the drive and assign
them to parameters A2-01 through A2-32. Registered parameters can
be displayed in [User Parameters] under the main menu. The user
can immediately access necessary parameters.
Note:
Settings for A2-01 to A2-32 vary depending on the value selected
for A1-06 [Application Preset].
V/f
CL-V/f
OLV
CLV
AOLV
Determines if the drive automatically saves the history of parameter
changes to A2-17 to A2-32 [User Parameters 17 to 32].
0 : Disabled
1 : Enabled
10.4 A: Initialization Parameters
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0000
575
(0000 - 9999)
0
575
(0 - 7)
0
590
(0 - 2)
0
590
(0, 1)
Default Setting
Ref.
(Range)
Parameters in
591
General-Purpose
Setup Mode
(Determined by
A1-07)
Determined by A1-
591
06
(0, 1)
399
10

Advertisement

Table of Contents
loading

Table of Contents