Main SP Tables-2-1
[LD Power: Fixed]
2221
Decides output setting value as the value set to this SP when not controlling
Process control.
001 K
002 C
003 M
004 Y
2229
[Develop DC Vias]
Standard Speed: Bk
001
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: Bk)
Standard Speed: C
002
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: C)
Standard Speed: M
003
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: M)
Standard Speed: Y
004
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: Y)
Middle Speed Bk
005
Refers to develop bias set to this SP when electric potential control with
Process control is not set.
Middle Speed C
006
Refers to develop bias set to this SP when electric potential control with
Process control is not set.
D146/D147/D148/D149/D150
*ENG
*ENG
[0 to 200 / 100 / 1%/step]
*ENG
*ENG
*ENG
[0 to 800 / 550 / 1-V/step]
*ENG
[0 to 800 / 550 / 1-V/step]
*ENG
[0 to 800 / 550 / 1-V/step]
*ENG
[0 to 800 / 550 / 1-V/step]
*ENG
[0 to 800 / 550 / 1-V/step]
*ENG
[0 to 800 / 550 / 1-V/step]
2-198
System Maintenance Section