SC No.
Level
SC994-00
C
SC No.
Level
SC997-00
D
SM
Error Name/Error Condition/Major Cause/Solution
Operation error caused by abnormalities that are normally
undetectable.
An error occurred because the number of records exceeded the
limit for images managed in the service layer of the firmware.
This can occur if there are too many application screens open
on the operation panel.
Logging only.
Error Name/Error Condition/Major Cause/Solution
Application function selection error
The application selected by the operation panel key operated
abnormally (No response, abnormal ending).
Software bug (mainly the application)
§
Check the optional RAM, DIMM, boards required by the
application program.
§
Check if the combination of downloaded programs are
correct.
5-197