Service Call 501-584
SC No.
Level
SC522-00
C
SC No.
Level
SC530-00
D
D146/D147/D148/D149/D150
Error Name/Error Condition/Major Cause/Solution
Paper Exit Motor: Lock
During motor ON, after checking the motor error notification
registers (err_velo and err_posi) for 500msec, the error state of
either register was detected at least 5 times.
§
Motor defective
§
Connector disconnected
§
Harness broken
§
IOB defective
§
Encoder defective
§
Replace the motor
§
Reset the connector
§
Replace the harness
§
Replace the IOB
Error Name/Error Condition/Major Cause/Solution
Fusing Exhaust Heat Fan Lock
In the motor ON state, the value of the lock sensor is checked
every 100msec.
If a lock signal is not obtained for 50 times consecutively.
§
Motor defective
§
Connector disconnected
§
Harness broken
§
IOB defective
§
Replace the motor
§
Reset the connector
§
Replace the harness
§
Replace the IOB
§