Ricoh D146 Service Manual page 775

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-1
028 Temp.:End:SRA3:Thick
1119
[Aging Temp. Correction]
001 Page(%)
002 Rotation(%)
011 Temp.:Plain:FC
012 Temp.:Plain:BW
013 Temp.:Plain:Energy Saving
1121
[Switch:Rotation Start/Stop]
Time:After Reload
001
Do not change. Time for to switch form reload to standby.
Time:After Recovery
002
Do not change. Standby transition: Changes time out time till depressuring.
Time:After Job
003
Do not change. Time for to switch form before paper through to standby.
Press Temp.:After Reload
004
Do not change. Pressure thresh to apply time to switch from reload to standby
End Temp.:After Job:SRA3
005
Do not change. Rotation start temperature for equaling edge part heat after
paper through (A3<paper width, pressure edge part)
-
006
Do not change. Rotation start temperature for equaling edge part heat after
paper through (DLT<paper width<=A3, pressure edge part)
-
007
Do not change. Rotation start temperature for equaling edge part heat after
paper through (B4<paper width<=DLT, pressure edge part)
D146/D147/D148/D149/D150
*ENG
[-30 to 30 / 20 / 1deg/step]
*ENG
[0 to 100 / 10 / 1%/step]
*ENG
[0 to 100 / 10 / 1%/step]
*ENG
[0 to 20 / 0 / 1deg/step]
*ENG
[0 to 20 / 0 / 1deg/step]
*ENG
[0 to 20 / 10 / 1deg/step]
*ENG
[0 to 100 / 60 / 1sec/step]
*ENG
[0 to 100 / 15 / 1sec/step]
*ENG
[0 to 100 / 60 / 1sec/step]
*ENG
[0 to 160 / 160 / 1deg/step]
*ENG
[0 to 250 / 200 / 1deg/step]
*ENG
[0 to 250 / 200 / 1deg/step]
*ENG
[0 to 250 / 200 / 1deg/step]
2-56
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents