Ricoh D146 Service Manual page 1205

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables - 4
Latest:BO
Displays SSCG Digital correction value (F Side/BLUE/ODD pixel).
006
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
4639
[SSCG Noise Cancel (Analog)]
Factory Setting:RE
Display/Saves Factory SSCG Analog correction value (F Side/RED/EVEN
pixel).
001
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:RO
Display/Saves Factory SSCG Analog correction value (F Side/RED/ODD pixel).
002
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:GE
Display/Saves Factory SSCG Analog correction value (F Side/GREEN/EVEN
pixel).
003
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:GO
Display/Saves Factory SSCG Analog correction value (F Side/GREEN/ODD
pixel).
004
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
D146/D147/D148/D149/D150
*ENG
[-255 to 255 / 0 / 1digit/step]
*ENG
[-31 to 31 / 0 / 1digit/step]
*ENG
[-31 to 31 / 0 / 1digit/step]
*ENG
[-31 to 31 / 0 / 1digit/step]
*ENG
[-31 to 31 / 0 / 1digit/step]