Ricoh D146 Service Manual page 1158

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Current:Y
004
Displays the latest Development gamma (Y).
Target:K
011
Displays Target Value for Development gamma (K).
Displays environment correction amount of develop gamma.
Environ Corr:Col
042
Displays environment correction amount of develop gamma.
TnrDensity Corr:K
051
Displays toner density correction amount of develop gamma. (K)
TnrDensity Corr:C
052
Displays toner density correction amount of develop gamma. (C)
TnrDensity Corr:M
053
Displays toner density correction amount of develop gamma. (M)
TnrDensity Corr:Y
054
Displays toner density correction amount of develop gamma. (Y)
TnrDensity:K
061
Displays Toner Density (K) converted based on TD Sensor output.
TnrDensity:C
062
Displays Toner Density (C) converted based on TD Sensor output.
TnrDensity:M
063
Displays Toner Density (M) converted based on TD Sensor output.
System Maintenance Section
[0.10 to 6.00 / 0.95 / 0.01
*ENG
mg/cm2/-kV/step]
[0.50 to 2.55 / 0.95 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
*ENG
[0.0 to 25.5 / 0.0 / 0.1 wt%/step]
*ENG
[0.0 to 25.5 / 0.0 / 0.1 wt%/step]
*ENG
[0.0 to 25.5 / 0.0 / 0.1 wt%/step]
2-439
Main SP Tables-3
D146/D147/D148/D149/D150