Ricoh D146 Service Manual page 1207

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables - 4
Factory Setting:GO
Display/Saves Factory SSCG Digital correction value (F Side/GREEN/ODD
pixel).
004
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:BE
Display/Saves Factory SSCG Digital correction value (F Side/BLUE/EVEN
pixel).
005
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:BO
Display/Saves Factory SSCG Digital correction value (F Side/BLUE/ODD pixel).
006
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
4641
[SSCG Noise Amplitude]
RE
Displays SSCG Nose Amplitude (F Side/RED/EVEN pixel) when adjusting
SSCG.
001
Correction value will be decided depending on detected Noise Amplitude when
adjusting.
Adjustment will be done when scanner turns on.
Use for design evaluation, analyzing malfunction (abnormal images).
D146/D147/D148/D149/D150
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[0 to 1023 / 0 / 1digit/step]
2-488