Main SP Tables-3
TnrDensity:Y
064
Displays Toner Density (Y) converted based on TD Sensor output.
Environ Corr1:K
071
Sets environment correction table value (environment section 1) of develop
gamma.
Environ Corr2:K
072
Sets environment correction table value (environment section 2) of develop
gamma.
Environ Corr3:K
073
Sets environment correction table value (environment section 3) of develop
gamma.
Environ Corr4:K
074
Sets environment correction table value (environment section 4) of develop
gamma.
Environ Corr5:K
075
Sets environment correction table value (environment section 5) of develop
gamma.
Environ Corr6:K
076
Sets environment correction table value (environment section 6) of develop
gamma
Environ Corr1:Col
081
Sets environment correction table value (environment section 1) of develop
gamma.
D146/D147/D148/D149/D150
*ENG
[0.0 to 25.5 / 0.0 / 0.1 wt%/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.04 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.06 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.08 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.10 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.10 / 0.01
*ENG
mg/cm2/-kV/step]
[-1.00 to 1.00 / 0.00 / 0.01
*ENG
mg/cm2/-kV/step]