Do not change. Threshold to decide low temp. environment
Temp.: Threshold: High
002
Do not change. Threshold to decide high temp. environment
Low Temp. Correction
003
Do not change. Correction temp. for stand up, standby when under low temp.
environment
High Temp. Correction
004
Do not change. Correction temp. for stand up, standby when under high temp.
environment
Job Low Temp. Correction
005
Do not change. Correction temp. for pass trough paper when under low temp.
environment
Job High Temp. Correction
006
Do not change. Correction temp. for pass trough paper when under high temp.
environment
Job Low Temp. Correction:Sp.
007
Do not change. Special mode correction temp. for pass trough paper when
under low temp. environment
Job High Temp.
Correction:Sp.
008
Do not change. Special mode correction temp. for pass trough paper when
under high temp. environment
Standard Environment Temp.
011
Do not change. Standard environment temperature
System Maintenance Section
*ENG
[0 to 100 / 30 / 1deg/step]
[0 to 15 / D146:5, D147:5, D148:15,
*ENG
D149:15, D150:15 / 1deg/step]
*ENG
[0 to 15 / 0 / 1deg/step]
[0.0 to 100.0 / D146:5.0, D147:5.0,
*ENG
D148:10.0, D149:10.0, D150:10.0 /
0.1deg/step]
*ENG
[0.0 to 100.0 / 0.0 / 0.1deg/step]
[0.0 to 100.0 / D146:5.0, D147:5.0,
*ENG
D148:10.0, D149:10.0, D150:10.0 /
0.1deg/step]
*ENG
[0.0 to 100.0 / 0.0 / 0.1deg/step]
*ENG
[10 to 30 / 23 / 1deg/step]
2-45
Main SP Tables-1
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents