Ricoh D146 Service Manual page 867

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-2-1
0: Set to correction value using table.
1: Set to Fixed Value: Electrify DC Voltage of SP.
043 DC Bias Fixed Value Set
[Charge DC Voltage: Correction]
2005
Fixed value of Vc calculating coefficient for DC Electrify.
Correction Coefficient a: Fixed
044
K
Correction Coefficient a: Fixed
045
C
Correction Coefficient a: Fixed
046
M
Correction Coefficient a: Fixed
047
Y
Correction Coefficient b: Fixed
048
K
Correction Coefficient b: Fixed
049
C
Correction Coefficient b: Fixed
050
M
Correction Coefficient b: Fixed
051
Y
Correction Coefficient c: Fixed
052
K
Correction Coefficient c: Fixed
053
C
Correction Coefficient c: Fixed
054
M
Correction Coefficient c: Fixed
055
Y
2005
[Charge DC Voltage: Correction]
D146/D147/D148/D149/D150
*ENG
[0 or 1 / 0 / 1/step]
*ENG
*ENG
[0.000 to 2.000 / 1.000 / 0.001/step]
*ENG
*ENG
*ENG
[0 to 2000 / 0 / 1/step]
*ENG
[0 to 2000 / D146: 20, D147: 20,
*ENG
D148: 0, D149: 0, D150: 0 / 1/step]
*ENG
*ENG
[0 to 100 / 0 / 1/step]
*ENG
[0 to 100 / D146: 10, D147: 10,
*ENG
D148: 0, D149: 0, D150: 0 / 1/step]
*ENG
2-148
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150