Ricoh D146 Service Manual page 756

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Plain1:BW:Press:Low Speed
104
Do not change. paper through target temperature: Standard 1: BW: pressure:
low speed
Plain2:FC:Center:Low Speed
Paper through target temperature: Standard 2: FC: center: low speed
105
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
Plain2:FC:Press:Low Speed
106
Do not change. paper through target temperature: Standard 2: FC: pressure:
low speed
Plain2:BW:Center:Low Speed
Paper through target temperature: Standard 2: BW: center: low speed
107
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
Plain2:BW:Press:Low Speed
108
Do not change. paper through target temperature: Standard 2: BW: pressure:
low speed
M-thick:FC:Center:Low Speed
Paper through target temperature: middle thick paper: FC: center: low speed
109
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
M-thick:FC:Press:Low Speed
110
Do not change. paper through target temperature: middle thick paper: FC:
pressure: low speed
M-thick:BW:Center:Low
111
Speed
System Maintenance Section
*ENG
[0 to 200 / 118 / 1deg/step]
*ENG
[100 to 180 / 120 / 1deg/step]
*ENG
[0 to 200 / 118 / 1deg/step]
*ENG
[100 to 180 / 120 / 1deg/step]
*ENG
[0 to 200 / 118 / 1deg/step]
*ENG
[100 to 180 / 135 / 1deg/step]
*ENG
[0 to 200 / 118 / 1deg/step]
*ENG
[100 to 180 / 135 / 1deg/step]