Ricoh D146 Service Manual page 852

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
Duplex Enter
CW:Mid-thick:Std
059
Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
Duplex Enter CW:Thick1:Low
060
Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1a: 73mm/s, Metis-C1b: 73mm/s
Duplex Enter CW:Thick1:Mid
061
Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1c: 108mm/s, Metis-C1d: 108mm/s, Metis-C1e: 108mm/s
Duplex Enter CW:Thick2:Low
062
Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1 all: 73mm/s
Duplex Enter CW:Thick3:Low
063
Prevents coat strips, waving, image sore. Reflect adjusted value as they are
Metis-C1 all: 73mm/s
Duplex CW:Plain:Low
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
064
image position accuracy improve. Reflects adjusted value as they are. All:
73mm/s, 1200dpi mode
Duplex CW:Plain:Std
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
065
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
System Maintenance Section
*ENG
[-4.0 to 4.0 / 0.5 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.8 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.8 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.8 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.7 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.7 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.7 / 0.1%/step]
2-133
Main SP Tables-1
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents