Main SP Tables-2-1
Sets edge detecting threshold value of Image transfer belt / TMP sensor test
mode.
The results will turn out as following in Image transfer belt / TMP sensors test
mode.
§
When TMP sensor detection value is larger than this setting value: No
problems.
§
When TMP sensor detection value is smaller than this setting value: Edge
detected.
2115
[Gamma Correction]
Low CPP edge Correction
Sets gamma correction value of valid pixel for low CPP edge process.
001
§
Value increase: Deeper density
§
Value decrease: thinner density
2117
[Skew Adjustment]
Pulse: M
001
M: skew adjust: input
Pulse: C
002
C: skew adjust: input
Pulse: Y
003
Y: skew adjust: input
2118
[Skew Adjustment]
Execute: M
001
M: skew adjust: execute
Execute: C
002
C: skew adjust: execute
Execute: Y
003
Y: skew adjust: execute
D146/D147/D148/D149/D150
*ENG
[0 to 100 / 80 / 1%/step]
*ENG
[-75 to 75 / 0 / 1pulse/step]
*ENG
[-75 to 75 / 0 / 1pulse/step]
*ENG
[-99 to 99 / 0 / 1pulse/step]
ENG
[0 or 1 / - / -]
ENG
[0 or 1 / - / -]
ENG
[0 or 1 / - / -]
2-176
System Maintenance Section