Ricoh D146 Service Manual page 876

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Temp Threshold M
007
Temperature variation threshold for deciding of executing main control.
0: Execute every time when set.
RH Threshold M
008
Relative humidity variation threshold for deciding of executing main adjust.
0: Execute every time.
AH Threshold M
009
Relative humidity variation threshold for deciding of executing main adjust.
0: Execute every time.
Temp Threshold S
010
Temperature variation threshold to do sub adjust.
0: Do every time
RH Threshold S
011
Relative humidity variation threshold to do sub adjust.
0: Do every time
AH Threshold S
012
Absolute humidity variation threshold to do sub adjust.
0: Do every time if conditions match.
Non-use Time
013
Threshold of time stopping photoreceptor continuously for main adjust.
0: Do not.
AC Current Error Detection
014
Flag to decide whether to adjust AC when SC491 is detected.
System Maintenance Section
*ENG
[0 to 99 / 10 / 1deg/step]
*ENG
[0 to 99 / 50 / 1%RH/step]
*ENG
[0 to 99 / 6 / 1g/m^3/step]
*ENG
[0.0 to 20.0 / 1.0 / 0.1deg]
*ENG
[0 to 50 / 5 / 1%RH/step]
*ENG
[0.0 to 20.0 / 1.0 / 0.1g/m^3/step]
*ENG
[0 to 1440 / 360 / 10min./step]
*ENG
[0 or 1 / 0 / 1/step]
2-157
Main SP Tables-2-1
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents