Ricoh D146 Service Manual page 1150

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Displays Development Potential: Current Value (M) according to paper.
Target:Y
104
Displays Development Potential: Current Value (Y) according to paper.
Target Corr:K
111
Displays develop potential target value correction amount (K).
Target Corr:C
112
Displays develop potential target value correction amount (C).
Target Corr:M
113
Displays develop potential target value correction amount (M).
Target Corr:Y
114
Displays develop potential target value correction amount (Y).
Vk:Upper_K
121
Regulates upper limit of start developing voltage value (K).
Vk:Upper_Col
122
Regulates upper limit of start developing voltage value (Col).
Vk:Lower_K
123
Regulates lower limit of start developing voltage value (K).
Vk:Lower_Col
124
Regulates lower limit of start developing voltage value (Col).
[LD Power :Set]
Sets background potential
3623
§
Default: 100V
§
Carrier deposit will occur when setting value too high.
001 Std Speed Slope:K
002 Std Speed Slope:C
003 Std Speed Slope:M
System Maintenance Section
*ENG
[0 to 800 / 0 / 1V/step]
*ENG
[-128 to 127 / 0 / 1/step]
*ENG
[-128 to 127 / 0 / 1/step]
*ENG
[-128 to 127 / 0 / 1/step]
*ENG
[-128 to 127 / 0 / 1/step]
*ENG
[0 to 255 / 30 / 1-V/step]
*ENG
[0 to 255 / 30 / 1-V/step]
*ENG
[-128 to 0 / -90 / 1-V/step]
*ENG
[-128 to 0 / -60 / 1-V/step]
*ENG
[-1000 to 1000 / D146, D147: 213,
*ENG
D148: 221, D149, D150: 233 /
1/step]
*ENG
2-431
Main SP Tables-3
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents