Main SP Tables-2-1
Display:Energized:C
030
Voltage correction value C, from Electrify roller fatigue.
Display:Energized:M
031
Voltage correction value M, from Electrify roller fatigue.
Display:Energized:Y
032
Voltage correction value Y, from Electrify roller fatigue.
Display:Total Rotation:K
033
Voltage correction value K, from Electrify roller total electrification.
Display:Total Rotation:C
034
Voltage correction value C, from Electrify roller total electrification.
Display:Total Rotation:M
035
Voltage correction value M, from Electrify roller total electrification.
Display:Total Rotation:Y
036
Voltage correction value Y, from Electrify roller total electrification.
Split Number n: K
037
Coefficient K, for setting electric potential to multiple steps from total
electrification time.
Split Number n: C
038
Coefficient C, for setting electric potential to multiple steps from total
electrification time.
Split Number n: M
039
Coefficient M, for setting electric potential to multiple steps from total
electrification time.
D146/D147/D148/D149/D150
*ENG
[0 to 90 / 0 / 1V/step]
*ENG
[0 to 90 / 0 / 1V/step]
*ENG
[0 to 90 / 0 / 1V/step]
*ENG
[0 to 30 / 0 / 1V/step]
*ENG
[0 to 30 / 0 / 1V/step]
*ENG
[0 to 30 / 0 / 1V/step]
*ENG
[0 to 30 / 0 / 1V/step]
*ENG
[1 to 99 / 15 / 1/step]
[1 to 99 / D146: 15, D147: 15,
*ENG
D148: 15, D149: 13, D150: 10 /
1/step]
[1 to 99 / D146: 15, D147: 15,
*ENG
D148: 15, D149: 13, D150: 10 /
1/step]