Sc Logging; Sc Automatic Reboot - Ricoh D146 Service Manual

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Self-Diagnostic Mode
Pattern
Display
The SC is
displayed on the
operation panel,
D
and the machine
cannot be used
(machine-error
SC).
§
When an ordinary SC (type D) is generated, an automatic reboot is performed. When an
event is reported by the customer support system, even in the event of an ordinary SC,
reboot is not performed. During automatic reboot, a confirmation screen is displayed after
the reboot.
§
When automatic reboot occurs twice continuously, an SC is displayed without rebooting,
and logging count is performed. Also, when an SMC print is output, an * mark is added
alongside the SC number for clarity.
§
Automatic reboot can be enabled or disabled with SP5-875-001 (SC automatic reboot
setting) (default value: ON).

SC logging

When an SC is generated, the "total count value when the SC is generated" and the "SC code"
are logged. However, if the total count value during the SC is the same as last time, logging is not
performed.
Logged data can be checked by outputting an administrative report (SMC print). The SC history is
logged up to the last 10 entries, and if there are more than 10 entries, data are progressively
deleted starting from the oldest.

SC automatic reboot

When an ordinary SC (pattern D) is generated, automatically reboot is performed. Automatic
reboot or reboot by user operation can be set by SP5-875-001 (SC automatic reboot setting out)
(default value: 0 "Automatic reboot").
However, when a NRS report is performed, a reboot is not performed even in the case of the
corresponding SC.
D146/D147/D148/D149/D150
How to reset
Switch user reset power key or main power
switch OFF to ON.
5-2
SC call or SC
alarm in
customer
support system
Occurrence &
alarm count
Power supply
OFF
ON
Alarm count
and alarm only
if recurrence
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150