Ricoh D146 Service Manual page 581

Hide thumbs Also See for D146:
Table of Contents

Advertisement

SC No.
Level
SC702-05
D
SC No.
Level
SC720
SC720-03
B
SC No.
Level
SC720
SC720-10
B
SM
Error Name/Error Condition/Major Cause/Solution
Motor defective or a harness short-circuit occurs in the
non-interlocking power supply system.
§
Replace the blown fuse or circuit board
§
Replace the short-circuited parts
Protection Device Intercept Error 5 (1-pass ADF)
Motor defective in the paper feed motor, pullout motor,
intermediate motor, scanner motor or paper exit motor, or a
harness short-circuit occurs, and the protection device of the
interlocking power supply system intercepts.
Motor defective or a harness short-circuit occurs in the
interlocking power supply system.
§
Replace the blown fuse or circuit board
§
Replace the short-circuited parts
Error Name/Error Condition/Major Cause/Solution
2K/3K Sheet finisher Error
Protection Device Intercept Error 1 (2K/3K sheet finisher)
Protection device intercept error state (fuse break) is detected.
§
Short-circuit defective
§
Overload defective
§
Motor defective
§
Solenoid defective
§
Check the harness
§
Replace the controller
§
Replace the motor
§
Replace the solenoid
Error Name/Error Condition/Major Cause/Solution
2K/3K Sheet finisher Error
Entrance Transport Motor Error (2K/3K sheet finisher)
5-107
Service Call 700-792
D146/D147/D148/D149/D150