Special2:FC:Press
034
Do not change. paper through target temperature: special paper 2: FC:
pressure
Special2:BW:Center
035
Paper through target temperature: special paper 2: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
Special2:BW:Press
036
Do not change. paper through target temperature: special paper 2: BW:
pressure
Special3:FC:Center
037
paper through target temperature: special paper 3: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
Special3:FC:Press
038
Do not change. paper through target temperature: special paper 3: FC:
pressure
039 Special3:BW:Center
System Maintenance Section
[0 to 200 / D146:118, D147:118,
*ENG
D148:118, D149:143, D150:143 /
1deg/step]
[100 to 180 / D146:139, D147:139,
*ENG
D148:141, D149:157, D150:157 /
1deg/step]
[0 to 200 / D146:118, D147:118,
*ENG
D148:118, D149:137, D150:137 /
1deg/step]
[100 to 180 / D146:139, D147:139,
*ENG
D148:141, D149:157, D150:157 /
1deg/step]
[0 to 200 / D146:118, D147:118,
*ENG
D148:118, D149:137, D150:137 /
1deg/step]
[100 to 180 / D146:139, D147:139,
*ENG
D148:141, D149:157, D150:157 /
1deg/step]
2-33
Main SP Tables-1
D146/D147/D148/D149/D150