Main SP Tables-1
Fusing Exit Fan Op Sw Temp
007
Sets temperature threshold for when switching operation of fusing exhaust heat
fan.
Ozone Fan Low Speed Op Sw
Temp
009
Sets temperature threshold for when switching to low speed operation of fusing
exhaust heat fan.
Ozone Fan Middle Speed Op
Sw Temp
010
Sets temperature threshold for when switching to middle speed operation of
fusing exhaust heat fan.
Ozone Fan High Speed Op
Sw Temp
011
Sets temperature threshold for when switching to high speed operation of fusing
exhaust heat fan.
Ozone Fan Low Noise Op
DUTY
012
Sets working duty when running ozone fan quiet.
Ozone Fan Low Speed Op
DUTY
013
Sets working duty when running ozone fan low speed..
Ozone Fan Middle Speed Op
DUTY
014
Sets working duty when running ozone fan middle speed.
Ozone Fan High Speed Op
DUTY
015
Sets working duty when running ozone fan high speed.
Paper Exit Cooling Fan Op
Start Time
016
Sets start operation time of paper exit cooling fan.
D146/D147/D148/D149/D150
*ENG
[0.0 to 100.0 / 0.0/ 0.1deg/step]
*ENG
[0.0 to 100.0 / 35.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 37.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 40.0 / 0.1deg/step]
*ENG
[0 to 100 / 20 / 1%/step]
*ENG
[0 to 100 / 30 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 900 / 300 / 1sec/step]
2-144