Do not change. paper through target temperature: special paper 1: BW:
pressure: low speed
1106
[Fusing Temp. Display]
Heat Center
001
Display fusing temperature: Displays detect temperature of heating center
sensor.
Heat End
002
Display fusing temperature: Displays detect temperature of heating edge
sensor.
Press Center
003
Display fusing temperature: Displays detect temperature of pressuring edge
sensor.
Press End
004
Display fusing temperature: Displays detect temperature of pressuring edge
sensor.
Press End
005
Display fusing temperature: Displays detect temperature of pressuring
extension edge sensor.
1107
[Standby Target Temp. Setting]
Stanby/Preheat1:Center
001
Do not change. Ready/pre-heat 1 target temperature: center
Preheat2:Center
003
Do not change. Pre-heat 2 target temperature: pressure
Low Power:Center
005
Do not change. Energy save target temperature: pressure
System Maintenance Section
ENG
[-10 to 250 / 0 / 1deg/step]
ENG
[-10 to 250 / 0 / 1deg/step]
ENG
[-10 to 250 / 0 / 1deg/step]
ENG
[-10 to 250 / 0 / 1deg/step]
ENG
[-10 to 250 / 0 / 1deg/step]
*ENG
[0 to 200 / 90 / 1deg/step]
*ENG
[0 to 200 / 90 / 1deg/step]
*ENG
[0 to 200 / 60 / 1deg/step]