Duplex CCW:Mid-thick:Std
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
073
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 146mm/s, Metis-C1b: 146mm/s, Metis-C1c: 186mm/s, Metis-C1d:
256mm/s, Metis-C1e: 256mm/s
Duplex CCW:Thick1:Low
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
074
image position accuracy improve. Reflect adjusted value as they are
Metis-C1a: 73mm/s, Metis-C1b: 73mm/s
Duplex CCW:Thick1:Mid
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
075
image position accuracy improve. Reflect adjusted value as they are Metis-C1c:
108mm/s, Metis-C1d: 108mm/s, Metis-C1e: 108mm/s
Duplex CCW:Thick2:Low
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
076
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
Duplex CCW:Thick3:Low
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
077
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
Duplex CCW:Thick4:Low
Prevent shock jitter by adjusting sub scan scale, scale error rate declination,
078
image position accuracy improve. Reflect adjusted value as they are Metis-C1
all: 73mm/s
System Maintenance Section
*ENG
[-4.0 to 4.0 / 1.1 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 1.2 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 1.2 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 1.2 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.9 / 0.1%/step]
*ENG
[-4.0 to 4.0 / 0.9 / 0.1%/step]