Ricoh D146 Service Manual page 766

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Permit
Temp.:Delta:Press:M-humid:No
Decurl
006
Do not change. Curl correction approve temperature: diff.: pressure: middle
humidity: de-curler not went through
Permit
Temp.:Delta:Press:H-humid:No
Decurl
007
Do not change. Curl correction approve temperature: diff.: pressure: middle
humidity: de-curler not went through
CPM:M-humid
008
Do not change. Curl correction CPM: middle humidity
CPM:H-humid
009
Do not change. Curl correction CPM: high humidity
CPM:M-humid:No Decurl
010
Do not change. Curl correction CPM: middle humidity: de-curler not went through
CPM:H-humid:No Decurl
011
Do not change. Curl correction CPM: high humidity: de-curler not went through
1114
[Heat Storage Status]
Temp.:Threshold:Press
001
Do not change. Pressuring temperature thresh to judge heat accumulation.
Temp.:Threshold:Atmosphere
002
Do not change. Audience temperatures thresh to judge heat accumulation.
Temp.:Threshold:CPM down
003
Do not change. Pressuring temperature thresh to judge heat accumulation.
Temp.:Threshold:Voltage
004
Detection
System Maintenance Section
[0 to 200 / D146:50, D147:50,
*ENG
D148:30, D149:30, D150:30 /
1deg/step]
[0 to 200 / D146:40, D147:40,
*ENG
D148:20, D149:20, D150:20 /
1deg/step]
*ENG
[0 to 100 / 80 / 1%/step]
*ENG
[0 to 100 / 65 / 1%/step]
*ENG
[0 to 100 / 80 / 1%/step]
*ENG
[0 to 100 / 65 / 1%/step]
*ENG
[0 to 200 / 80 / 1deg/step]
*ENG
[0 to 200 / 60 / 1deg/step]
*ENG
[0 to 200 / 60 / 1deg/step]
*ENG
[0 to 200 / 40 / 1deg/step]
2-47
D146/D147/D148/D149/D150
Main SP Tables-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents