Main SP Tables-1
Do not change. Heating center target temperature of abnormal sound check
control
Heat End Target Temp
006
Do not change. Heating edge target temperature of abnormal sound check
control
Press Target Temp
007
Do not change. Pressuring target temperature of abnormal sound check control
1154
[Switch:Rotation Start/Stop]
Judging Method Change
001
Do not change. Switches Over heat prevent mode.
-
005
Do not change. Heater On timing of start rotate/stop control
Overshoot Prevent Temp.:SC
006
Do not change. Rotate start temperature of over heat prevent mode when error
occurs.
[Small Size Paper Control]
1155
Do not change. Small size heater control.
001 Print Width
[Short Heater Control]
1155
Do not change. Small size heater control.
Feed Permit
011
Temp.:delta:Center
D146/D147/D148/D149/D150
ENG
[100 to 180 / 130 / 1deg/step]
ENG
[0 to 200 / 0 / 1deg/step]
[0 or 1 / 0 / 1/step]
*ENG
0: On
1: Off
*ENG
[0 to 250 / 50 / 10msec/step]
[0 to 250 / D146:185, D147:185,
*ENG
D148:195, D149:200, D150:200 /
1deg/step]
ENG
[0 to 300 / 0 / 1mm/step]
ENG
[0 to 200 / 5 / 1deg/step]
2-86
System Maintenance Section