Service Call 620-689
SC No.
Level
SC637-02
D
SC No.
Level
SC650-01
B
D146/D147/D148/D149/D150
Error Name/Error Condition/Major Cause/Solution
Tracking Information Notification Error (Management server
error)
Tracking information was lost.
Communication with tracking management server failed.
§
Network error
§
tracking management server error
§
Tracking SDK application error
Turn the main power off/on.
Error Name/Error Condition/Major Cause/Solution
Remote Service Modem Communication Error (Dialup
authentication failure)
§
An error related to communication (dialup connection,
modem board etc.) using the RC Gate Type M was detected
or an error that prevents RC Gate operation was detected at
power on.
§
Displayed only when an error is detected while RC Gate is
operating.
§
SC is not issued if an error occurs during RC Gate
installation (because it can be referenced using SP).
Dialup authentication failure
Check the following SPs.
§
SP5-816-156
§
SP5-816-157
5-94