Main SP Tables-2-1
PWM: Center
Saves / Refreshes PWM setting value of TMP sensor [Center] to this setting
006
value when Vsg adjustment is done.
From then on, PWM setting value will be this setting value during belt check.
When Vsg adjust fails, saving / refreshing will not be done to this setting
PWM: Rear
Saves / Refreshes PWM setting value of TMP sensor [Rear] to this setting
007
value when Vsg adjustment is done.
From then on, PWM setting value will be this setting value during belt check.
When Vsg adjust fails, saving / refreshing will not be done to this setting
2141
[TM/ID Sensor Check Result]
Average: Front
005
Saves / Refreshes TMP sensor [Front] detecting result average data to this SP
from result of Image transfer belt / TMP sensor check mode.
Average: Center
006
Saves / Refreshes TMP sensor [Center] detecting result average data to this
SP from result of Image transfer belt / TMP sensor check mode.
Average: Rear
007
Saves / Refreshes TMP sensor [Rear] detecting result average data to this SP
from result of Image transfer belt / TMP sensor check mode.
D146/D147/D148/D149/D150
*ENG
[0 to 1023 / 0 / 1/step]
*ENG
[0 to 1023 / 0 / 1/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
*ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
2-178