Ricoh D146 Service Manual page 1206

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Factory Setting:BE
Display/Saves Factory SSCG Analog correction value (F Side/BLUE/EVEN
pixel).
005
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:BO
Display/Saves Factory SSCG Analog correction value (F Side/BLUE/ODD
pixel).
006
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
4640
[SSCG Correction Value (Dig.)]
Factory Setting:RE
Display/Saves Factory SSCG Digital correction value (F Side/RED/EVEN pixel).
001
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:RO
Display/Saves Factory SSCG Digital correction value (F Side/RED/ODD pixel).
002
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
Factory Setting:GE
Display/Saves Factory SSCG Digital correction value (F Side/GREEN/EVEN
pixel).
003
Adjusted SSCG correction Value during the main unit warranty process is
saved.
Use for analyzing malfunction, comparing factory / current value.
System Maintenance Section
*ENG
[-31 to 31 / 0 / 1digit/step]
*ENG
[-31 to 31 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
ENG
[-255 to 255 / 0 / 1digit/step]
2-487
Main SP Tables - 4
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents