Ricoh D146 Service Manual page 1161

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-3
Sets toner density threshold for correction using TC correction term of develop
gamma (target).
TC Corr ThreshHold:Y
094
Sets toner density threshold for correction using TC correction term of develop
gamma (target).
3630
[Dev gamma :Disp/Set]
UpperLimit
101
Displays initial value of develop gamma (K).
LowerLimit
102
Displays initial value of develop gamma (C).
[Dev gamma :Disp/Set]
3630
Displays latest develop gamma.
111 Current:F_K
112 Current:F_C
113 Current:F_M
114 Current:F_Y
121 Current:C_K
122 Current:C_C
123 Current:C_M
124 Current:C_Y
131 Current:R_K
132 Current:R_C
133 Current:R_M
D146/D147/D148/D149/D150
*ENG
[7.0 to 12.0 / 9.0 / 0.1wt%/step]
[1.00 to 5.00 / 5.00 /
*ENG
0.01mg/cm2/-kV/step]
[0.10 to 1.00 / 0.15 /
*ENG
0.01mg/cm2/-kV/step]
[0.10 to 6.00 / 0.90 /
ENG
0.01mg/cm2/-kV/step]
ENG
[0.10 to 6.00 / 0.80 /
ENG
0.01mg/cm2/-kV/step]
ENG
[0.10 to 6.00 / 0.90 /
ENG
0.01mg/cm2/-kV/step]
ENG
[0.10 to 6.00 / 0.80 /
ENG
0.01mg/cm2/-kV/step]
ENG
[0.10 to 6.00 / 0.90 /
ENG
0.01mg/cm2/-kV/step]
ENG
[0.10 to 6.00 / 0.80 /
0.01mg/cm2/-kV/step]
ENG
2-442
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents