Main SP Tables-1
Have pressuring time for side fence of one action bypass tray (for truing up the
paper) When making this value larger than necessary, side effects might occur
like thin paper buckling.
Postcard_SEF/Envelope Choukei 3_SEF Th
035
Adjoining paper width threshold with side fence position sensor of one action
bypass tray.
[Initial Operation Setting]
1009
Switches 1: ON 0: OFF of register back rush removal when recovering form
sleep mode. With default setting, this is OFF prior less noise.
Registration Gear Backlash
001
Cut
1101
[Reload Permit Setting]
Pre-rotation Start Temp.
001
Do not change. Temperature for when to switch form no rotate heating to stand up
heating.
Reload Target Temp.:Center
002
Do not change. Reload permission target temperature: center
D146/D147/D148/D149/D150
[0 or 1 / 0 / 1/step]
*ENG
0:OFF
1:ON
*ENG
*ENG
2-12
[0.000 to 3.300
*ENG
/ 0.000 /
0.001V/step]
[0 to 200 / 0 /
1deg/step]
[0 to 190 /
D146:123,
D147:123,
D148:141,
D149:157,
D150:157 /
1deg/step]
System Maintenance Section