Level
SC915-01
A
SC915-02
A
SC915-03
A
SC915-04
A
SC915-05
A
SC No.
Level
SC919-00
D
SM
Error Name/Error Condition/Major Cause/Solution
External Controller Error 6 (Egret board error)
External Controller Error 6 (HDD serial communication error)
External Controller Error 6 (CPU temperature rise)
External Controller Error 6 (Unable to communicate with GW
controller because invalid command was received)
External Controller Error 6(Unable to communicate with GW
controller because of an error)
Notification from external application (external controller)
Notification from external application (external controller)
Replace the Egret controller board.
Error Name/Error Condition/Major Cause/Solution
External controller down
While EAC (External Application Converter), the conversion
module, was operating normally, the receipt of a power line
interrupt signal from the FLUTE serial driver was detected, of
BREAK signal from the other station was detected.
External controller and the machine had been operating
correctly (*) but the external controller was turned off or
rebooted, or the video bus was disconnected.
* Printing or scanning using the external controller.
Turn the main power off/on.
5-193