3522
[Drum Stop Environ :Disp]
Temperature
001
Displays (temperature) of when imaging finished.
Rel Humidity
002
Displays (relative humidity) of when imaging finished.
Abs Humidity
003
Displays (absolute humidity) of when imaging finished.
3529
[ProCon Interval Control :Set]
Gamma Corr
001
Sets ON/OFF develop gamma correction for Pro-Con auto execute interval.
Environ Corr
002
Sets ON/OFF environment correction for Pro-Con auto execute interval.
AbsHum Threshhold
003
Sets absolute humidity threshold of environment correction for Pro-Con auto
execute interval.
Max Cnt Threshhold
004
Sets max. count threshold of Interrupt Pro-Con/Job end Pro-Con.
Exe Cnt
005
Sets max. count counter of Interrupt Pro-Con/Job end Pro-Con.
Page Cnt:BW
006
Displays Pro-Con (BW) sheets count.
007 Page Cnt:FC
System Maintenance Section
*ENG
[-1280.0 to 1270.0 / 0.0 / 0.1deg]
*ENG
[0.0 to 1000.0 / 0.0 / 0.1%RH/step]
*ENG
[0.0 to 1000.0 / 0.0 / 0.1g/m3/step]
[0 or 1 / 1 / 1/step]
*ENG
0: OFF
1: ON
[0 or 1 / 1 / 1/step]
*ENG
0: OFF
1: ON
*ENG
[0.0 to 99.0 / 4.3 / 0.1g/m3/step]
*ENG
[0 to 99 / 2 / 1counts/step]
ENG
[0 to 255 / 0 / 1counts/step]
*ENG
[0 to 5000 / 0 / 1sheet/step]
*ENG
[0 to 5000 / 0 / 1sheet/step]
2-407
Main SP Tables-3
D146/D147/D148/D149/D150