Sharp IV-S20 User Manual page 97

Compact image sensor camera
Table of Contents

Advertisement

(2) Input terminals (INPUT) X5 and X6
Parallel selection input
(External input/reference image registration etc. and
X5
measurement number specification (lower bits))
Specify in item 5PARALLEL INPUTX5 on the [I/O
SETTINGS] menu.
Parallel selection input
(External input/image change etc. and measurement
X6
number specification (upper bits))
Specify in item 6PARALLEL INPUTX6 on the [I/O
SETTINGS] menu.
(3) Output terminals (OUTPUT) Y0 to Y7 and BUSY
Result of logical calculation output
Y0
- Specify in item rFINAL OUTPUT COND on the [OBJECT TYPE COND] menu.
to Y7
=> See page 10-8 to 13.
When "BUSY" is active, this terminal outputs an ON signal while the IV-S20 is
executing the measurement and opening the all set menu.
When "READY" is active, this terminal outputs an ON signal while the IV-S20 is
BUSY
waiting for a trigger.
- To specify "BUSY" or "READY," go to item 7OUTPUT STATUS in the "I/O
SETTINGS" menu. Seetings => See page 11-1. Time chart, etc. => See page 11-
4 to 11-15.
(4) Input/output port
The input/output terminals are isolated by photocouplers, to prevent malfunctions due to noise.
Use them within the rated range. The specifications of the input/output ports are listed below.
Item
Rated input voltage
Input voltage range
Input
Input voltage level
Input current level
Input impedance
Rated output voltage
Load voltage range
Rated max. output current
Output
Output type
ON voltage drop
Isolation method
Response time
(5) Wiring to IV-S20 main housing
[When X5 and X6 are used to
specify a measurement number]
Rating
12/24 VDC
10.5 to 26.4 VDC
ON: 10.5 V or less OFF: 5 V or more
ON: 3 mA or less OFF: 1.5 mA or more
3.3 k
12/24 VDC
10.5 to 27 VDC
20 mA DC
NPN transistor, open collector
1.2 V or less (20 mA)
Isolated by photocoupler
1 ms or less (OFF to ON, ON to OFF)
Input
X0
X6
C(+)
6- 15
Installation Conditions and Method
Measurement
X6
to be executed
Measurement 0
OFF
Measurement 0&1
OFF
Measurement 0&2
ON
Measurement 0&3
ON
(See page 11-1 and 11-2.)
Output
L
L
L
Y0
Y7
BUSY
X5
OFF
ON
OFF
ON
6
Fuse
(0.5A)
C(-)

Advertisement

Table of Contents
loading

Table of Contents