Connecting To The Input/Output Terminals (Parallel I/F) - Sharp IV-S20 User Manual

Compact image sensor camera
Table of Contents

Advertisement

Installation Conditions and Method

[4] Connecting to the input/output terminals (parallel I/F)

7 input terminals and 9 output terminals are available on the input/output terminal block on the IV-S20
main housing.
The input terminal block has INPUT terminals X0 to X6 and C (+), and the output terminal block has
OUTPUT terminals Y0 to Y7, BUSY and C (-).
Input/output terminal block on the IV-S20 main housing
6
(1) Input terminals (INPUT) X0 to X4
X0
X1 to 4
*1
*2
Input terminals (INPUT)
X0
X1
X2
X3
X4
X5 X6
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
Output terminals (OUTPUT)
INPUT
X0
X1
X2
X3
X4
X5
Y0
Y1
Y2
Y3
Y4
OUTPUT
INPUT
POWER
X0
X1
X2
X3
X4
X5
X6
C(+)
+24V
0V
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
BUSY
C(-)
OUTPUT
VIDEO CAMERA1 CAMERA2
RS232C/RS422
- Measurement start input/output setting condition *1 - External input
- Measurement start input/output setting condition *2 - Measurement start input
- Measurement start input/output setting condition *1 - External input
- Measurement start input/output setting condition *2 - Object type input (0 to 15)
Object type
X4
X3
0
OFF
OFF
1
OFF
OFF
2
OFF
OFF
3
OFF
OFF
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
ON
Input/output condition setting (See Chapter 11.)
Measurement start input I/F = General purpose serial interface signal
Measurement start input I/F = CCD trigger
CCD sampling start = General purpose serial interface signal or auto detect (edge or level)
Measurement start input I/F = Parallel
Measurement start input I/F = CCD trigger, CCD sampling start = Parallel interface
C(+)
C(–)
BUSY
POWER
X6
C(+)
+24V
0V
Y5
Y6
Y7
BUSY
C(-)
IV-S20 main housing
IV-S20
POWER
REMOTE
Object type
X2
X1
OFF
OFF
8
OFF
ON
9
ON
OFF
10
ON
ON
11
OFF
OFF
12
OFF
ON
13
ON
OFF
14
ON
ON
15
6-14
X4
X3
X2
X1
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON

Advertisement