9-1 Outline

The measuring conditions for each object type are set on the [OBJECT TYPE COND ] (conditions for object
type) menu.
[Settings screen]
On the MAIN OPS MENU, move the cursor to SET-SCRN item, and press the SET key
- On the [SYSTEM SETUP] menu, move the cursor to item 2 OBJECT TYPE COND
and press the SET key.
[OBJECT TYPE COND]
1OBJECT TYPE NO.
2EDIT
3TITLE REGISTRATION (TO NEXT SUB-MENU)
4MEAS.0, CAMERA1
5POS. ADJ.CAMERA1
6MEAS.0, CAMERA2
7POS. ADJ.CAMERA2
8SELECT CAMERA IMG NO CAM1 CAM1 CAM1&2
9COMPARE IMAGES
0MEASUREMENT 1
qMEASUREMENT 2
wMEASUREMENT 3
eFINAL CALC RESULT
rFINAL OUTPUT COND (TO NEXT SUB-MENU)
tSYSTEM-IN/OUT
yHALT MEAS ON NG
uUPPER MENU
[Setting procedure]
Enter the object type number (0 to 15)
Editing (copying and initialization)
Selecting the difference between
images calculation
Setting the measurement program
conditions
No
Correct the camera position?
Set position correction value
Set final value numeric calculation
Set final output condition
Setting the system input/output
conditions
Enabling/disabling a halt on an NG
measurement
To return to [SYSTEM SETUP]
menu
Save in flash memory
00(0~15)
COPY(
NO (TO NEXT SUB-MENU)
NO ADJ. [REG. 0-1PNTSXY
NO (TO NEXT SUB-MENU)
NO ADJ. [REG. 0-1PNTSXY
NO SUB.I1 T1 DIFF.ABS I1 T1
NO (TO NEXT SUB-MENU)
NO (TO NEXT SUB-MENU)
NO (TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
NO YES
Items set on the [OBJECT TYPE COND] menu.
1
2EDIT: See Editing in section 9-2 [7] and [8].
8 SELECT CAMERA IMG, 9 COMPARE IMAGES
See section 9-2 [6].
4MEAS.0, CAMERA 1
6MEAS.0, CAMERA 2
0MEASUREMENT 1
qMEASUREMENT 2
wMEASUREMENT 3
5POS. ADJ. CAMERA 1
7POS. ADJ. CAMERA 2
Yes
· Determine whether or not correct image position which will be
mesured by measurement 1 to 3 based on the measure positional
deviation by the measurement 0.
eFINAL CALC RESULT
rFINAL OUTPUT COND
tSYSTEM-IN/OUT
yHALT MEAS ON NG
See item (2) Halting on an NG measurement
uUPPER MENU
9-1
Setting The Criteria For Each Object Type
TYPE00) INITIALIZE
· Unless item
"NO," then item
also be displayed.
TYPE NO.
See item (1) outline of setting
the measurement program
See section 9-2 [5]
See section 9-2 [4].
See Chapter 10
See section 9-11 and Chapter 11
8
is set to
9
will
9

Advertisement