Editing After Initialization - Sharp IV-S20 User Manual

Compact image sensor camera
Table of Contents

Advertisement

[8] Editing after initialization

When you first start to set all of the parameters, we recommend that you initialize the conditions first.
The contents required to initialize are as follows.
- All of the conditions
- Measurement conditions of each measurement program - (1)
- Measurement conditions of each type number
(1) Initialize measurement conditions for each measurememt program number
The IV-S20 will always start up with the measuring program for an object type which has been
specified and stored in the memory (RAM). If the measurement 0 program was specified, then a
camera number will also have been specified.
- Any measurement conditions stored in flash memory will remain as they were before
initialization.
[Operation procedure for measurement program 0]
- This example shows the initialization of object type 01, measurement 0, camera 1:
measurement of positional deviation.
On the MAIN OPS MENU, move the cursor to SET-SCRN item, and press the SET key.
- On the [SYSTEM SETUP] menu, move the cursor to 2 OBJECT TYPE COND
(conditions of object type) and press the SET key.
- On the conditions for object types menu [OBJECT TYPE COND], set item 1OBJECT
TYPE NO. (object type number) to 01 and select item 4 MEAS.0, CAMERA 1
1.Select item 3 INITIALIZATION, using the up and down keys and press the
2.When the SET key is pressed, the initialization will begin.
[Operation procedure for measurement programs 1 to 3]
- This is an example of the initialization of object type 02, measurement 1.
On the MAIN OPS MENU, move the cursor to SET-SCRN, and press the SET key.
- On the [SYSTEM SETUP] menu, move the cursor to 2 OBJECT TYPE COND and
press the SET key.
- On the [OBJECT TYPE COND] (conditions for object type) menu, set item 1
OBJECT TYPE NO. to 02 and select 0 MEASUREMENT 1.
1.Select item 5 INITIALIZATION (initialize), using the up and down keys and
2.When the SET key is pressed, the initialization will begin.
[TYPE00-MEAS0]
1SELECT MEAS. TYPE
2COPY :
3INITIALIZATION
4MEAS. PROG. COND
1
5EVALUATION COND
6NUMERIC CALC COND
7OUTPUT CONDITIONS
8UPPER MENU
SET key.
[TYPE00-MEAS1]
1MEAS SELECTION NO
2COMPARE IMAGES NO YES(CAM1)
3SELECT CAMERA CAM1 CAM2
4COPY
5INITIALIZATION
1
6MEAS.PROG. COND (TO NEXT SUB-MENU)
7EVALUATION COND (TO NEXT SUB-MENU)
8NUMERIC CALC COND (TO NEXT SUB-MENU)
9OUTPUT CONDITIONS (TO NEXT SUB-MENU)
0UPPER MENU
press SET key.
9-31
- See 12-1 [3] Total initialization
- (2)
NO MEAS-POSITION-DEVIATE
EXEC TYPE00 CMR1POS-DEVIATION
EXEC
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
CHECK-DEG-OF-MATCH
DST&AGL MES. (GRAY&EDGE GRAV)
INSPECT-LEAD MEASR-BIN-AREA
CNT-BIN-OBJ LABEL-BIN-OBJ
POINT MEAS
EXEC TYPE00 MEAS1 NO
EXEC