Degree of match inspection
Continued form the previous page
Pressing the TRG/BRT key will run a check by starting a manual measurement.
Shown below is an example of how the display will look when the gray scale search mode has been
selected and both models 0 and 1 have been set to (Search YES).
[Display of the inspection
result]
Final evaluation result
Measuring time
Measurement number and
camera number
Registration number for the
measurement condition
Degree of match with the
reference image for model 0
Detected coordinates for model 0
Average light level for model 0
Degree of match for model 1
Detected coordinates for model 1
Average light level for model 1
· By moving the cursor to REG-CHNG (change registration) and pressing the up key, you can see the
measurement results for different registration numbers and numerical calculations. This is done by
scrolling through them in the following order: Registration numbers 00 01 02,...,15,00.... These are
followed by the results of the numerical calculations N00 to N15. The measurements screen also has
9
this feature. Pressing the down key in these situations will scroll back through the results in the
opposite order.
· Unregistered numbers will be skipped.
· When there are no recorded numbers (other than those currently on display) or if no measurement has
actually been carried out, then it will not be possible to switch back and forth between data.
(TYPE00)
OK
MEAS. XXXXXXms
MEAS1 CAM1 DEG OF MATCH
REGST NO. 00(0~15)
MATCH.(MDL 0) +09878 OK
X COORD. (MDL 0) X=288.0 OK
Y COORD. (MDL 0) Y=190.0 OK
LIGT LVL(MDL 0) 023.0
MATCH.(MDL 1) +09306 OK
X COORD. (MDL 1) X=389.0 OK
Y COORD. (MDL 1) Y=355.0 OK
LIGT LVL(MDL 1) 023.0
X0~6
Y0~7
:
:
MSR-CHNG REG-CHNG PC-MONTR SET-SCRN MANL-TYP-CHG
9·56
OK
Model 0
OK
BUSY
:
Model 1