Sharp IV-S20 User Manual page 349

Compact image sensor camera
Table of Contents

Advertisement

Computer Link
2 Example using an A1SJ71UC24-R4 module
[Switch setting]
Ex.: To set as below:
Mode: RS-422, Transmission speed: 19.2 K bytes/sec.
Parity: Even, Stop bit: 2bits
(2) Using memory
To allow the memory to be used by the IV-S20, use a result write start address within the following
range.
Note: To write data from the IV-S20 to a Mitsubishi PC, use the WW/QW write command. The range
that can be written using the write command WW/QW is D0000 to D1023/D000000 to
D008191, due to the limitation of Mitsubishi PCs. The write all address can be set within the
range of limitation for Mitsubishi PCs. (See page 11-19.)
14
SW
STATION No.
ON OFF
01
7
6
02
03
5
4
04
3
05
7
06
6
07
5
08
4
3
09
B
10
A
9
11
8
7
12
6
5
Memory
D (data register)
8
9
0
10
1
2
8
9
1
0
1
2
C
D
E
F
0
1
2
3
4
Range (address)
0 to 999900
14-24