Sharp IV-S20 User Manual page 311

Compact image sensor camera
Table of Contents

Advertisement

(5) Corrected light level reading: code 29
The corrected light level measured by the illuminance monitor function, the evaluation result and
preset reference light level are read.
Ë
Command
: 2 9
SC
SC
CR
(H)
(L)
Ë Response
Object
type
: 2 9
RC
RC
(H)
(L)
- Object type _ Object type for which the measurement was executed: 00 to 15
- Result _ 0: NG, 1: OK
- Corrected light level _ Corrected light level (±0 to 255.0)
- Reference light level _ Light level used as the criterion (0 to 255.0)
(H)
- Camera No. _ 1: camera 1, 2: camera 2
Corrected
Reference
light level
light level
2
1
0
-1
2
1
0
10
10
10
10
10
10
10
10
13-11
SC
SC
CR
-1
(H)
(L)
Communication