[3] Evaluation conditions

The setting details and procedures for setting the evaluation conditions are the same for all
measurement programs.
In this section we explain the use of the [EVALUATION COND] (evaluation conditions) menu when
counting quantities by binary conversion.
Evaluation conditions [EVALUATION COND] menu for counting quantities by binary conversion
[EVALUATION COND] (TYPE00-MEAS.1-CNT-BIN-OBJ)
1 REGST NO.
0(0~3)
2 NUMBER
00000~59999
3 TOTAL AREA
000000~245760
4 MAKE A TEST RUN (SET KEY)
5 UPPER MENU
· Items in the regtangle
measuremet program.
Evaluation conditions
1 REGST NO.
(registration number)
2 NUMBER
(number of objects)
3 TOTAL AREA
4 MAKE A TEST RUN
5 UPPER MENU
[The setting procedure]
Enter the registration number corresponding
to the registration number from the
[MEASURING COND] (measurements
condition) menu
Make the measurements
Enter the upper and lower limits for an OK
judgment.
Enter the target to output data
Record evaluation conditions
Not done
The recording is finished
Return to the [TYPE00-MEAS 0 to 3] menu.
[TEST RESULT]
00004
OK
002000
OK
are the same for each
Set to 0 to 3 corresponds to the registration number item
(registration number) on the measurement condition menu [MEASURING
COND].
Set the range for the number of objects which will produce an OK judgment.
Set the range for the total surface area which will produce an OK judgment.
To carry out a MAKE A TEST RUN of the evaluation conditions, push the
SET key. The results will be displayed.
This will also record the details of the settings.
Return to the [TYPE00-MEAS 0 to 3] menu.
The setting headings from the
[EVALUATION COND] (evaluation
conditions) menu above.
Done
9-13
Using the up and down keys, you can
set the output to NO (no output), Y0
to 7 (output on these relays), or C000
to C127 (output on these secondary
[OUT]
relays), in the output area of the
NO
menu.
NO
(If the test result returns OK, then the
output is turned ON. If it is NG, then it
is turned OFF).
When carrying out a test using item
MAKE A TEST RUN, on the menu, the
resulting measurement values and the
evaluation (OK or NG) will be displayed.
Settings details
1 REGST NO. (registration number)
4
2 NUMBER (number of objects)
3 TOTAL AREA (total surface area)
4
TEST RUN (make a stest run)
5 UPPER MENU
Shared settings
,
REGT.NO
9
make a test run)