4. Press the ESC key, move the cursor to 3 SEARCH AREA (search window) and press the
SET key.
5. Create a search window (dotted line) to be used as the search area.
- The search area is the area within which the new image will be searched for a match with
the image stored in step 3. The gray scale search function performs the search operation
(see the "Glossary").
- The procedure for defining the search area is the same as in step 3.
Search window
- After defining the search window size and position, press the ESC key.
6. Move the cursor to w UPPER MENU and press the SET key.
- The screen will return to the [MEASURING COND] (measurement conditions) menu.
7. Press the ESC key.
- The screen will return to the [TYPE00-MEAS0] (type: 00, measurement: 0) menu.
(8) Operation on the [EVALUATION COND] (evaluation condition) menu
1. Move the cursor to 5 EVALUATION COND and press the SET key.
- The [EVALUATION COND] menu will be displayed.
REGST NO.
2
X COORD.(MDL0)
COORD.(MDL0)
X DEVIAT(MDL0)
DEVIAT(MDL0)
MATCH(MDL0)
3
MAKE A TEST RUN
4
UPPER MENU
5
2. Move the cursor to 1 REGST NO. (register number) and press the SET key. Move the
number to 0 with the up and down keys, and press the SET key.
3. Move the cursor to 6 MATCH (MDL0) and press the SET key.
4. Move the cursor to the lower limit position with the left and right keys, and press the SET key.
- Select the digit to change with the left and right keys, and then set the value to +09000 with
the up and down keys.
(Criteria for a successful match: 90.00% to 100.00%)
6MATCH(MDL0
- After defining the lower limit, press the SET key.
5. Press the ESC key, move the cursor to r UPPER MENU and press the SET key.
- The screen will return to the [TYPE00-MEAS0] (type: 00, measurement: 0) menu.
6. Press the ESC key.
- The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
Continued on the following page
COND
(TYPE00-MEAS0-POS-DEVIATION)
0(0 7)
000.0 511.0
000.0 479.0
000.0 511.0
000.0 479.0
10000
10000
(SET KEY)
+09000~+10000
3-11